Chapter 3 Troubleshooting
GLC1320G-55 User’s Guide
23
2 Connect your computer to the console port and use terminal emulation software configured to the
following parameters:
3 Pull out the line card and push it back in to restart it and begin a session.
4 When you see the
Press any key to enter Debug Mode within 3 seconds message,
press a key to enter debug mode.
5 Type
atba5 after the Enter Debug Mode message (this changes the console port speed to
115200 bps).
6 Change the configuration of your terminal emulation software to use 115200 bps and reconnect to
the line card.
7 Type
atur after the Enter Debug Mode message.
8 Wait for the
Starting XMODEM upload message before activating XMODEM upload on your
terminal.
9 This is an example Xmodem configuration upload using HyperTerminal. Click Transfer, then Send
File to display the following screen.
Figure 5 Example Xmodem Upload
VT100 terminal emulation 9600 bps
No parity, 8 data bits, 1 stop bit No flow control
Type the firmware file's
location, or click Browse to
search for it.
Choose the 1K Xmodem
protocol.
Then click Send.